Ultrae-logo
The appearance of the calibration-free micro disposable pH electrode/Humming Probe UH1/UltraE
The Schematic diagram of pH measurement of micro liquid samples with the calibration-free micro disposable pH electrode/Humming Probe UH1
The Schematic diagram of the pH  electrode extension cable for the calibration-free micro disposable pH electrode/Humming Probe UH1
The calibration-free micro disposable pH electrode/Humming Probe pH electrode UH1 can be steadily stored in dry vials
The outer packaging of the calibration-free micro disposable pH electrode/Humming Probe pH electrode UH1//UltraE

Humming Probe UH1

pH-test paper/ pH test strip/ pH measurement/ pH strip electrode/ single use pH sensor

  • Unique features are as follows:
  • ・Accurate, calibration-free, ready-to-use
  • ・Ultra small sample requirement (10~20uL)
  • ・Disposable to avoid sample cross-contamination
  • ・Accuracy can reach ±0.1 pH
  • ・Each strip has a built-in temperature sensing element
  • ・Portable
  • ・Long shelf life single use pH sensor

Operation

YouTube Video

免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針可提供微升級的樣品測試/Humming Probe UH1/超極生技UltraE

Why is the Humming Probe pH Measurement
System/pH Meter Calibration-free?

Patented hydrogen ion exchange film design

Supply electrodes with fixed reaction area

We use the patented hydrogen ion adsorption film, in addition to selectively allowing hydrogen ions in the sample to pass through,to avoid the passivation caused by the adsorption of other matrices in the sample on the surface of the electrode and simplifies the sample processing steps. Furthermore, the surface-exchangeable hydrogen ion content in the Nernst equation, which affects the Ek' value, can be precisely controlled by the design of the hydrogen ion adsorption film.
....
專利氫離子吸附膜設計_UH1

Automated production technology

Make every electrode look "the same"

Automated production machine can quickly introduce R&D results into the production process for the most efficient bridging of R&D and production.The automatic production machine (G1) can achieve a CV value of 3~5% for the production stability of test strips through automated production model. In addition, we have developed different types of automated machines for different manufacturing process requirements, such as temperature sensing component assembly machines, to increase production stability and consistent quality.
....
自動化生產技術_UH1
Calibration before leaving the factory

Each test strip has been calibrated

Each test strip has been calibrated and verified using NIST traceability standards before leaving the factory, so you can simply take the test strip out of the vial and test pH directly.verified using NIST traceability standards before leaving the factory, so you can simply take the test strip out of the vial and test pH directly.
....
預先出廠前校正_UH1
Each strip is equipped with independent temperature sensing element

Smart temperature compensation for every test

Each test strip is embedded with an independent small-volume temperature sensing element. When the sample temperature is within the range of 10-40 degrees,even with a small quantity of sample, it also has automatic temperature compensation (ATC), and the resolution can reach ±0.01 pH.01pH。
....
每一片都設置獨立溫度感測元件_UH1

What makes the Humming Probe pH Strip
– UH1 special in addition to being free of calibration?

免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極樣品需求可降至微升級/Humming Probe UH1/超極生技UltraE
Measure in one drop
Sample requirements can be reduced to 10 microliters

Biological samples such as blood, saliva, cerebrospinal fluid, tissue fluid, etc…cannot be sampled in large quantities. Usually such small quantities of samples require the purchase of expensive ultra-small glass electrodes of pH meter to perform the test. UH1 can provide the perfect solution by dripping sample, or by dipping. *UH2 can provide sample requirements as small as 1 microliter (Learn about UH2)

免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極可用於體液檢測/Humming Probe UH1/超極生技UltraE

Body fluid (perspiration) detection

免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極可用於活體檢測/Humming Probe UH1/超極生技UltraE

Fermentation process control

Disposable design for single use pH sensor,
broaden the application in various fields

A brand-new test strip can be taken from the vial for each use and requires no time-consuming cleaning or maintenance after testing. For viscous or easily adsorbed samples or in combination with various special treatments, it breaks through the limitations of traditional glass electrodes and provides you with more applications.

免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極可用以經過滅菌滅活處理測試培養基酸鹼值/Humming Probe UH1/超極生技UltraE

Allows special treatment such as sterilization and inactivation

免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極可用以用於測試粘稠不易清理樣品/Humming Probe UH1/超極生技UltraE

Test viscous samples that are difficult to clean up

拋棄式UH1
Disposable Design
We provide high precision pH measurement. The values can be displayed to 0.01,and the accuracy can reach ±0.1 pH. Testing pH values from 0 to 14 can be satisfied.
....
免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極可用以測試pH0~14及精確度0.1pH/Humming Probe UH1/超極生技UltraE"
Liquid reference electrode not required
The reference liquid leakage problem is avoided with our uniquedesign for screen-printed electrode with ion membrane. You don’t need to worry about the reaction between reference electrode and your samples, such as protein samples. Thus, it is suitable for continuously monitoring for long time and applying in a wider range of samples.
....
免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極不含離子可用於蛋白質樣品/Humming Probe UH1/超極生技UltraE
Portable and easy storage
The thickness of traditional glass electrode’s glass film is only 0.1-0.3mm,so it is easy to break. For storage, it needs to be continuously immersed in liquid storage solution, so special care is needed for carrying. The special design of the Humming Probe does not contain any filling liquid. Small size, portable, just put it in the vial with a tight lid, suitable for mobile outdoor testing environment.
....
免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極無pH電極保存液方便攜帶/Humming Probe UH1/超極生技UltraE

How accurate is the Humming Probe pH Measurement System?

Compare the measured data with the NIST standard pH buffer value, and obtain the correlation coefficient according to the linear regression equation
NIST standard pH buffer 2 712
Sampling number 101010
AVG(pH) 1.99 6.99 11.97
SD(pH) 0.01 0.020.03
CV(%) 0.75%0.35%0.26%
Accuracy Rrange(pH) 0.050.080.09
Compare the measured data of UH1
with the NIST pH buffer value
Measurement range: pH0 - 14*
Slope: 1.0029
Intercept: -0.0521
Correlation coefficient: 0.9999

*pH 0 solution is 1.0 M HCl solution

pH 14 solution is 1.0 M NaOH solution SGS

IMG

Linearity

Linearity

便於攜帶

Precision

Precision

便於攜帶

Accuracy

Accuracy

便於攜帶
In terms of quality control, the production of all test strips and instruments is performed by UltraE. In addition to accurately mastering the production technology, we also control the product quality throughout the process. The test strips start from the raw material, through the substrate bare chip printing, to the high polymer film process and temperature sensor assembly process, and follows 100% full inspection process to ensure product stability. We are also officially ISO 9001:2015 certified, assuring our partners of quality and standardized processes.
ISO Certification
SGS Laboratory Test Report

Trusted by precision laboratory in universities and enterprises

How to use the Humming Probe pH Measurement System?

All products are calibrated and inspected using NIST traceability standards before leaving the factory, and each batch of calibration information is printed as QR code on the cap of the vial. Scan the QR Code when using the strip for the first time to load the technical parameter of the pH strip into the meter, and then the pH measurement can be performed directly.Unlike traditional glass electric appliances, the Humming Probe is extremely convenient, not requiring traditional and complicated calibration steps.

免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極的使用方法/Humming Probe UH1/超極生技UltraETake the pH strip electrode out from the vial.
免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極的使用方法/Humming Probe UH1/超極生技UltraEMeasuring method 1
Test by directly dropping samples onto the strip
免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極的使用方法/Humming Probe UH1/超極生技UltraEmethod 2
Put the pH strip electrode into the sample solution.

When should I use the Humming Probe
pH Measurement System?

Biological lab
The pH value for culture media or buffer solutions are usually adjusted to within 0.1 pH.Our product, the Humming Probe, is able to monitor the pH value of culture media at any time by directly insertion to make sure the cells and bacteria are growing under the correct environment.
....
Biological lab-UltraE
Outdoor on-site inspection
Traditional methods of monitoring outdoor environmental pollution often requiresamples to be taken to the laboratory for testing. Direct on-site testing is rarely used, and it often takes a long time to detect pollution problems. The Humming Probe pH Measurement System does not require you to carry a variety of calibration solutions, only requiring the pH meter and the pH strips, to perform direct on-site testing. The test results can be obtained quickly, the testing time can be greatly shortened, and the degree of pollution can be understood immediately.
....
Outdoor on-site inspection-UltraE
Biomedical detection field
Colorimetric methods to measure are commonly used instead of traditional pH meter, due to the low volume of biomedical samples such as blood, urine, or interstitial fluid.However, colorimetric methods are often difficult to obtain accurate data. In contrast, our Humming Probe only requires 1-20 μL volume of sample to perform testing. Moreover, the Humming Probe System can be integrated with other detection sensors through customization.
....
Biomedical detection field-UltraE
Agricultural field
The acidity and alkalinity (pH) of the soil is an important step in planting crops. The Humming Probe pH Measurement System can test soil pH directly in moistsoil or using a simple water-soluble medium to assist in plant growth management or soil improvement.
....
Agricultural field -UltraE
Food and beverage processing industry
In the process of producing food, pH value will affect the taste, freshness,and shelf-life of the final product. The design of the patented ionic membrane and disposable electrode of the Humming Probe pH strip can overcome the complex composition of the sample, which usually requires a pre-treatment process to accurately measure to provide accurate pH measurements for meat, fish, jam, seafood, milk, cheese, yogurt, dairy products, sauces, teas, etc.
....
Food and beverage processing industry-UltraE
Synthesis lab
No matter if you are doing organic, non-organic or polymer synthesis experiments,it is necessary to control the pH value in every phase under different reaction conditions. The Humming Probes pH meter can be directly dipped into small samples at different stages to obtain accurate pH values. Its disposable design can also avoid impurities on the electrodes or introducing contaminants to the system.
....
Synthesis lab-UltraE

Find your Humming Probe

Most Popular

UH1-蜂鳥探針
Classic

Suitable for most

UH1 pH STRIP
  • Suitable for liquid samples
  • Ultra small sample requirement: 10-20 μL
  • Suitable for single & continuous test

New

UH2蜂鳥探針
Micro-sample

Suitable for precious and micro samples

UH2 pH STRIP
  • Suitable for liquid samples
  • Ultra small sample requirement: 1-2 μL
  • Suitable for single & continuous test

New

UH2-Gas

Gas

Suitable for gas samples

UH2-Gas pH STRIP
  • Suitable for gas samples
  • Lower limit of detection
  • Suitable for single & continuous test

Find your meter and accessories

UX100 pH Meter

  • 4.3” Color Waterproof Touchscreen
  • Waterproof: IP54
  • Dual Mode Inspection Design
  • Built-In 5M Pixels Camera, Data Editable
UX100免校正酸鹼檢測儀

UX200 pH Meter

  • pH chart
  • 7” Color Touchscreen
  • Waterproof: IP54
  • Dual Mode Inspection Design
  • Built-In 5M Pixels Camera, Data Editable
UX200免校正酸鹼檢測儀

CS200 MAGNET INVERTER MIXER

  • Constant Temperature Control (20-40°C)
  • Digital Speed Control/Display (400-1500rpm)
  • Clockwise & Counter-Clockwise Design
  • Beaker Size Range (10-500 mL)
CS200 磁石變頻攪拌器

UH1 pH Strip Electrode

DM Download
免校正微量拋棄式pH酸鹼檢測電極/蜂鳥探針電極的尺寸規格及包裝規格/Humming Probe UH1/超極生技UltraE

Note: The pH Test Strip Electrode should always be capped and stored in the vial and only to be taken out when using. Each vial contains 25 pieces of pH test strip electrodes, and each box contains 2 vials.

Subscribe Us